Secured Trading Service

TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA

Hubei Tianrui Electronic Co., Ltd.
  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • High Sensitivity Core: Adopts high magnetic permeability core for good linearity and high sensitivity.
  • Stable Buckle Structure: Fixed buckle design ensures good stability and prevents sliding during operation.
  • Wide Current Range: Rated primary current spans from 400A to 1200A with 1.2 times overload capacity.
  • Flexible Output Options: Offers 1A or 5A secondary current with terminal output for easy connection.
  • Global Certifications: Compliant with RoHS, REACH, CE, and UL 94-V0 flame retardant standards.
  • Easy Installation: Split core design allows installation without power failure using simple latching.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA

TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA pictures & photos
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA pictures & photos
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA pictures & photos
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA pictures & photos
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA pictures & photos
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA pictures & photos
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
  • TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
  • TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
    TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
  • TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
    TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
  • TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
    TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
  • TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
    TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
  • TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
    TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
  • TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
    TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA

Find Similar Products

Product Description

TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
Main characteristics

The buckle structure is fixed and the stability is good
Adopt high magnetic permeability core, good linearity and high sensitively
Terminal output, easy to stall

Applications

Rural power grid reconstruction project
Online environmental monitoring
Smart fire-fightingpower consumption

Certificates

★RoHS/REACH compliant
★CE certificate
★UL flame retardant rating 94-V0(For the housing)

 
Electrical parameters
Type
TRFK-50C
Rated primary current
400A~1200A
Rated secondary current
1A,5A
Overload
1.2 times
 Rated capacity 1VA, 2.5VA, 3.75VA, 5VA, 10VA
Aperture
50mm
 Secondary load ≤ 0.2Ω
Ratio error@rated primary
±0.5%
Phase error@rated primary
≤60′
Working frequency
50/60Hz
Rms voltage for AC isolation test
(between primary and secondary)
3kV AC/1mA 10s
Relative humidity
≤90%
Operating ambient temperature
-25ºC~+75ºC
Storage temperature
-40ºC~+85ºC
Barometric condition
70kPa~106kPa
Application place
Indoor use
Secondary output type
Terminal output
Weight
Around 880g
Accuracy parameters
Input current(A)
1%In
5%In
20%In
100%In
120%In
Ratio error(%)
-
±1.5
±0.75
±0.5
±0.5
Phase error(′)
-
≤180
≤90
≤60
≤60
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VASuch as the specification is 200A/5A, When the input current is 200A, S1 and S2 as the output, S1 is connected to S3 in parallel, and S2 is connected to S4 in parallel. When the input current is 400A, S1 and S4 as output, S2 and S3 are connected in series.

Installation instructions

Warning: Please use professional and appropriate protective equipment to prevent electric shock and ensure safety.

Installation steps

Step1. Before installing, ensure that the circuit is in the state of power failure, or live installation operation, professional personnel are required.

Step 2. Open the protective cover of current transformer, connect the wire with the terminal output of the current.

transformer and connect it to the port of the measuring equipment, and ensure the circuit is closed. See Figure 1.

Step 3. Open the transformer latch and prepare for installation. See Figure 2.

Step 4. Place the cable inside the hole of current transformer. Ensure that the current direction of the cable is consistent with the arrow on the current transformer. Lock the latch again, and fix the cable with the nylon ties to hook both ends of the transformer to prevent sliding. See Figure 3.
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA

          Winding parallel connection method                                                                    Winding series connection method                
               Fig.1 Connect S1, S2, S3 and S4 with special cables according to the requirements of customers
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
                Winding parallel connection method                                        Winding series connection method
             Fig.2 Open the latch and run through the cable
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA
            Winding parallel connection method                                      Winding series connection method
          Fig.3 Lock the latch, and fix the cable using a nylon tie

TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA

TR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VATR Split Core Open Type AC Current Transformer Measurement CT1000: 1 2000: 1 1A 5A 1VA 2.5VA

About the Supplier

Watch Video
Watch Video
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.

About Our Factory & Business Background

Address
No. 8, Chuangye Avenue, Tianmen Economic Development Zone, Tianmen City, Hubei Province, Tianmen, Hubei, China
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main Products
Current Transformer, Current Sensors, Rogowski Coil, Voltage Transformer, AC DC Transmitter, Open Close Current Transformer, Inductomers, Power Transformer, Hall Sensor, Zero Sequence Current Transformer

Our Industry Experience & Global Business Record

Export Year
2015-12-12
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the rated primary current range?
The rated primary current ranges from 400A to 1200A.
What secondary current options are available?
We offer 1A and 5A secondary current options.
Can this transformer be used outdoors?
No, this product is designed for indoor use only.
Does the product have safety certifications?
Yes, it is RoHS/REACH compliant, holds a CE certificate, and the housing has UL 94-V0 rating.
How is the transformer installed?
It features a split core design; simply open the latch, place the cable inside, and lock the latch.
What is the aperture size?
The aperture size is 50mm.
What is the lead time for orders?
Peak season lead time is one month, while off-season lead time is within 15 workdays.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now