New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V

Product Details
Customization: Available
Type: Hall Type
Output Signal Type: Analog Output
Still deciding? Get samples of US$ 26.66/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
23709 square meters
  • New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
  • New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
  • New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
  • New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
  • New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
  • New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
TR0209-LKH-01
Production Process
SemiConductor Integrated
Material
Metal
Accuracy Grade
0.2-1
Application
Switching Power Supply
IP Rating
IP55
Certification
ISO CE RoHS
Customized
Customized
Current Consumption
<20mA
Bandwidth(-3dB)
DC~20kHz
Linearity
<1%Fs
Secondary Rated Output Voltage
4V
Transport Package
Standard Boxes
Specification
HOLE 20
Trademark
TR
Origin
China
HS Code
850450
Production Capacity
50000

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 20.00cm
Package Gross Weight
1.000kg

Product Description

Product Description

 

New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
 
New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
 
New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V


PRODUCT OVERVIEW
 
The sensor works on the principle of direct measurement Hall detection. The magnetic flux generated by the primary current is gathered in the magnetic circuit, and the Hall voltage signal is detected by the Hall device. After amplification by the amplifier, the voltage signal accurately reflects the primary current.
Product Features
 

Measures AC, DC and pulsed signals

Strong resistance to external interference, high common mode rejection ratio

Low temperature drift, low power consumption, wide frequency band

K/D structure, easy installation

Scope of Application
Scope of Application
 

AC frequency conversion speed regulation

Servo motor traction

Uninterruptible power supply(UPS)

Welding machine, battery power supply

Technical Parameter
Specification 50A/4V 200A/4V 500A/4V Unit
IPN Primary Rated Input Current 50 200 500 A
IP Primary Current Measurement Range 0~100 0~400 0~750 A
VSN Secondary rated output voltage 4 V
VC The Power Supply Voltage ±12~15(±5%) V
IC Current Consumption <20 mA
Vd Insulation Voltage Between primary and secondary circuits:5kV/50Hz/1min  
εL Linearity <1 %FS
X Precision TA=25ºC:≤±1 %
V0 Offset Voltage TA=25ºC:≤±20 mV
VOM Magnetic Offset Voltage IP=0 after 3*IPN:≤±20 mV
VOT Offset voltage temperature drift IP=0TA=-40~+80ºC:≤±1 mV/ºC
Tr Response time ≤20 μS
f Bandwidth(-3dB) DC~20 kHz
TA Working Temperature -40~+80 ºC
TS Storage Temperature -45~+85 ºC
RL Load Resistance TA=25ºC:≥10
New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V



New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V
Technical Parameter

New Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4VNew Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4VNew Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4VNew Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4VNew Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4VNew Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4VNew Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4VNew Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4VNew Energy Power Management AC/DC Open-Loop Direct Measurement Hall Current Sensor 50A/4V 200A/4V 500A/4V

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier