Product Highlights

  • High Precision Accuracy: Available in accuracy classes 0.2, 0.5, and 1.0 for different measurement requirements.
  • Flexible Output Modes: Supports both socket and lead output methods for versatile application integration.
  • Superior Balance Characteristics: Unbalanced current output is better than 30mA, 10mA, and 5mA with strong anti-interference.
  • High Sensitivity Core: Adopts high magnetic permeability nickel steel or nanocrystalline magnetic core.
  • Robust Construction: Casted with epoxy resin for good stability and flame retardant PBT/PC shell.
  • Compliant Standards: Meets GB 14287.2-2014 and GB 13955-2005 requirements for electrical fire monitoring.
  • Wide Operating Range: Rated input current 10mA~5A and linear range 5%~120% for diverse protection needs.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer

TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer pictures & photos
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer pictures & photos
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer pictures & photos
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer pictures & photos
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer pictures & photos
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer pictures & photos
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
  • TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
  • TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
    TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
  • TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
    TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
  • TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
    TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
  • TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
    TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
  • TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
    TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
  • TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
    TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer

Find Similar Products

Product Description

TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer

 

Product Overview
 
Residual current transformer for leakage current measurement of cable lines. The product is simple in structure and flexible in application. According to the cable specifications used in the main circuit, there are various core diameters corresponding to it. The main circuit current includes 63A~2000A. At the same time, it meets the requirements of balanced characteristics, and the unbalanced current output is better than 30mA, 10mA and 5mA. The product adopts high-quality high-conductivity magnetic core and advanced process technology, which can meet the technical requirements of different precisions such as 0.2, 0.5 and 1.0, and has high reliability. This series of products meet the requirements of GB 14287.2-2014 and GB 13955-2005.
Product Features
 

Flexible output mode, socket or lead output;

A variety of core hole diameter options, the hole diameter is from φ12mm to φ260mm;

Casting with epoxy resin, good stability;

Adopt high magnetic permeability nickel steel or nanocrystalline magnetic core, with good linearity and high sensitivity;

Excellent balance characteristics, with strong anti-electromagnetic interference ability.

Scope of Application
 
Suitable for motor protection, electromagnetic relay protection device, microcomputer protection device; electrical fire monitoring, fire leakage system, low current grounding system.
Product Parameters

Electric
Performance
Parameters
Operating Temperature -40ºC~+70ºC Relative Humidity ≤90%
Voltage Level 0.4/0.66/0.72kV Linear Range 5%~120%
Rated Input Current (AC) 10mA~5A Working Frequency 45~1250Hz
Rated Output (AC) 0~1V or 0~5mA Medium Strength: 3000V AC/min
Accuracy Class 0.5, 1.0, 2.0 Insulation Resistance >500MΩ/500V DC
Mechanical
Structure
Parameters
Shell Material PBT/PC Flame Retardant Grade 94-V0 Output Method Socket or Shielded Sheathed Wire
Iron Core Material Nickel Steel or Ultra Microcrystalline Construction Plan Base installation bolts are fixed
Sealing and Filling Epoxy Resin Environmental Requirements Meet RoHS
Typical Value of Main Products
Model NO. Input current rated Value AC Rated Continuous Thermal Current AC Common Transformation Ratio Accuracy Class Secondary Load(Ω) Dimensions(mm)
ApertureD Other size
TR21125B 10mA~5A 10A 1000:1
2000:1
0.2, 0.5 ≤200 25 L-W-H-J-A1-A2
80-22-69.5-68-5.2-8
TR21126B 10mA~5A 10A 1000:1
2000:1
0.2, 0.5 ≤500 45 L-W-H-J-A1-A2
120-33-101.5-98-5.2-8.5
TR21127B 10mA~5A 10A 1000:1
2000:1
0.2, 0.5 ≤500 55 L-W-H-J-A1-A2
150-35-126-126-5.2-12
TR2174B 10mA~5A 10A 1000:1
2000:1
0.2, 0.5 ≤500 35 L-W-H-J-A1-A2
100-30-90-83.5-5.2-9.5
TR21313B 10mA~5A 10A 1000:1
2000:1
0.2, 0.5 ≤500 32 L-W-H-J-A1-A2
91-28-70-80-5.5-7.5
TR21314B 10mA~5A 10A 1000:1
2000:1
0.2, 0.5 ≤500 45 L-W-H-J-A1-A2
104-28-83-93-5.5-7.5
TR21315B 10mA~5A 10A 1000:1
2000:1
0.2, 0.5 ≤500 65 L-W-H-J-A1-A2
126-28-105-115-5.5-7.5
TR21316B 10mA~5A 10A 1000:1
2000:1
0.2, 0.5 ≤500 80 L-W-H-J-A1-A2
143-28-122-132-5.5-7.5
TR21317B 10mA~5A 10A 1000:1
2000:1
0.2,0.5,1.0 ≤500 105 L-W-H-J-A1-A2
172-28-151-161-5.5-7.5
TR21117B 10mA~5A 10A 1000:1
2000:1
0.2,0.5,1.0 ≤500 72 L-W-H-J-A1-A2
175-42-150-150-6.2-13
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer
TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current TransformerTR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current TransformerTR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current TransformerTR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer

TR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current TransformerTR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current TransformerTR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current TransformerTR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current TransformerTR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current TransformerTR AC Electrical Fire Monitoring Closed Loop Residual Zero-Phase Current Transformer

About the Supplier

Watch Video
Watch Video
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.

About Our Factory & Business Background

Address
No. 8, Chuangye Avenue, Tianmen Economic Development Zone, Tianmen City, Hubei Province, Tianmen, Hubei, China
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main Products
Current Transformer, Current Sensors, Rogowski Coil, Voltage Transformer, AC DC Transmitter, Open Close Current Transformer, Inductomers, Power Transformer, Hall Sensor, Zero Sequence Current Transformer

Our Industry Experience & Global Business Record

Export Year
2015-12-12
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What accuracy classes are supported?
The transformer supports accuracy classes of 0.2, 0.5, and 1.0, allowing users to select the precision level that best fits their technical requirements.
What are the output method options?
The product features flexible output modes, supporting both socket output and lead output (shielded sheathed wire) for easy installation.
What standards does this product meet?
This series of products meets the requirements of GB 14287.2-2014 and GB 13955-2005, ensuring compliance with electrical fire monitoring and protection standards.
What is the rated input current range?
The rated input current (AC) ranges from 10mA to 5A, providing versatility for various low-current measurement and protection applications.
What materials are used for the magnetic core?
The product adopts high-quality high-conductivity magnetic cores, specifically high magnetic permeability nickel steel or nanocrystalline magnetic core, ensuring high linearity and sensitivity.