Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation

Product Details
Customization: Available
Application: Electronic, Instrument, Position Sensor, Audio, Lighting
Type: Current Transformer
Still deciding? Get samples of US$ 17/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
23709 square meters
  • Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
  • Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
  • Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
  • Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
  • Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
  • Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
TRSK-50A-02
Phase
Single
Operation Condition
Indoor
Usage
Measurement
Winding Form
Multilayer Honeycomb Type
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Rated Input Current
0~1500A
Rated Capacity
0~5va
Accuracy Class
0.5, 1.0
Winding Bobbin
PBT
Rated Frequency
50/60Hz
Opening-Closing Structure
Snap
Transport Package
Standard Boxes
Trademark
TR
Origin
China
HS Code
850450
Production Capacity
300000

Packaging & Delivery

Package Size
20.00cm * 20.00cm * 20.00cm
Package Gross Weight
1.500kg

Product Description

Product Description
Split-core Cable Type Current Transformer
26+ years of industry experience
Strong production and R&D team
Support customization of performance parameters and appearance OEM ODM
24-hour service, welcome to inquire

Product description
 
TR-A series open and close current transxformer,180 degrees open and close freely, indoor use. It can be quickly installed and disassembled in the state of no power failure and continuous line and the operation is simple ,Through the principle of electromagnetic induction ,the measured source is isolated from personnel and equipment ,effectively ensuring the safety of personnel and property. This series of products has a variety of apertures and specifications to meet different use and installation needs.
Product characteristics
 

The buckle structure is fixed and the stability is good;

According to the cable specifications used in the main circuit, there are various core hole diameters corresponding to it ;

Wide quantity limit and strong anti-saturation ability .Rated primary current range :1~1000A,rated secondary current range :0~5 A, current transformation ratio range can reach 100:1~10000:1;

Provide a variety of combined output methods: when outputting ampere-level current, you can use PVC sheathed wire terminals alone ,output Ma-level current, you can choose three-phrase integrated collection terminals and choose a variety of signal interfaces.

Adopt high magnetic permeability core, good linearity and high sensitively .

Application
 
Rural power grid reconstruction project, online environmental monitoring ,smart fire-fighting power consumption, low-voltage power distribution system, smart power consumption system, electricity measurement ,power quality analysis and electrical equipment signal collection ,lighting equipment such as power installations, small current grounding systems, etc.
Performance
Electrical

performance/p>

parameters
Operation temperature -40ºC~+70ºC Relative humidity ≤90%
Voltage level 0.4/0.66/0.72KV Linear range 5%~120%
Rated input current 0~1500A Rated frequency 50/60Hz
Rated capacity 0~5VA Power frequency withstand voltage 3KV/min
Accuracy class 0.5,1.0 Dielectric strength 1000MΩ/500V/min
Mechanical

structure

parameters
Shell PA/PC Flammability rating 94-V0 Output method PVC Sheathed cable/RJ12 Crystal terminal/PS/2Round head male interface
Winding bobbin PBT Opening-closing structure snap
Core material Silicon steel/manganese zinc ferrite Construction plan Nylon cable ties bundled and fixed cables
Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
 
Shape and installation dimensions
Product model rated input rated output accuracy class Dimensions(mm)
D L W H
TRFK-10A 0~75A 0~50mA (0~1.0V) 0.2
0.3
0.5
0.5s
9 34.5 37.5 45
TRFK-16A 0~150A 0~100mA (0~2.5V) 15 40.5 42.5 52
TRFK-24A 0~250A 0~100mA (0~5.0V) 22.5 54 47 71
TRSK-36-1A 0~300A 0~100mA (0~7.0V) 35 61 53 81
TRSK-36A 0~500A 0~100mA (0~7.0V) 35 66 53 87
TRSK-50-1A 0~600A 0~100mA (0~7.0V) 49 81 59 107.5
TRSK-50A 0~800A 0~100mA (0~7.0V) 50 88 59 114
TRSK-10A 5~100A 0~200mA (0.5VA) 0.5
0.5s
1.0
3.0
9 34.5 37.5 45
TRFK-16A 5~150A 0~1A (0.5VA 1VA) 15 40.5 42.5 52
TRFK-24A 10~300A 0~5A (0.5VA 2.5VA) 22.5 54 47 71
TRSK-36-1A 10~500A 0~5A (0.5VA 2.5VA) 35 61 53 81
TRSK-36A 10~600A 0~5A (0.5VA 3.75VA) 35 66 53 87
TRSK-50-1A 10~1000A 0~5A (0.5VA 3.75VA) 49 81 59 107.5
TRSK-50A 10~1500A 0~5A (0.5VA 5VA) 50 88 59 114
Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation
Trsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid RenovationTrsk-50A Split Core Current Transformer 50mm 500A/5A 600A/5A 800A/5A Online Environmental Monitoring Rural Power Grid Renovation

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier