Tr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDC

Product Details
Customization: Available
Type: Electromagnetic
Output Signal Type: Analog Output
Still deciding? Get samples of US$ 22.99/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
23709 square meters
  • Tr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDC
  • Tr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDC
  • Tr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDC
  • Tr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDC
  • Tr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDC
  • Tr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDC
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
TRJC100-20A
Production Process
Integration
Material
Plastic
Customized
Customized
Precision
0.05%
Linearity
0.02%
Ripple Current
2ua
Dynamic Response Time
1ua
Specification
HOLE 12
Trademark
TR
Origin
China
HS Code
850450

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 10.00cm
Package Gross Weight
0.500kg

Product Description

Product Description
Tr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDC
Tr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDC

Technology Characteristics
 1.Multichannel magnetic compensation feedback   
 2.Tiny misaligned currents                                                 6.Low temperature drift
 3.Superior linearity                                                             7.High isolation withstand            
 4.Small error between input & output                                8.Wide Frequency bandwidth
 5.Fast response speed                                                      9.High-resolution

Application
 1.New energy detection                                                     5.Battery pack detection         
 2.Power electronic measurement                                      6.Industrial control and measurement     
 3.Medical facility                                                                          7.Standard for laboratory testing

 4.ail traffic                                                                                            8.Instrument calibration
Certificate
 1.RoHS/REACH compliance
 2.CE certificate

 3.UL flame retardant rating 94-V0( For the housing)

Electrical performance

Type Symbol Test condition Min Rated Max Unit
Measuring range IPM   -- ±100 ±120 Adc
Power supply Vc Full range ±12 ±15 ±15.5 Vdc
Current consumption Ic Within the IPM  range ±20 ±120 ±140 mA
Ratio KN Input/Output 1000:1 --
Rated output current ISN Primary rated current -- ±100 -- mA
Measuring resistance RM Refer to Pic.1 -- 15 -- Ω
Precision Xe 25±10ºC -- -- 0.05 %
Linearity εL -- -- -- 0.02 %
Temperature drift coefficient TCR -- -- -- 0.1 ppm/ºC
Zero offset current Io 25±10ºC -- -- ±10 uA
Zero offset current IoT Full operating temperature range -- -- ±10 uA
Ripple current In DC~10Hz -- -- 2 uA
Dynamic response time tr 5% IPN up to 90%IPN -- -- 1 uA
di/dt accurately followed di/dt -- 200 -- -- A/us
Frequency bandwidth(- 3 dB) F -- 0 -- 100 kHz
Note: The rated current is rms current when measuring AC
General characteristic
Type Symbol Test condition Min Nominal Max Unit
Operating temperature range TA -- -40 -- +85 ºC
Storage temperature range TS -- -55 -- +100 ºC
Security feature
Type Symbol Test condition Min Nominal Max Unit
Isolated voltage withstand Between the primary and secondary Vd 50Hz,1min -- 5 -- kV
Transient isolation withstand voltage Between the primary and secondary Vw 50uS -- 10 -- kV
Tr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDCTr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDC
This product is molded part, ABS material, tolerance of shape and dimensions in accordance with GB/T14486-2008 MT6.
Lead wire output type, wire:  1332-20AWG/19-0.185TS/0D1.56, connected to XHB-4Y bayonet terminal.

Tr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDCTr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDC
Tr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDCTr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDCTr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDCTr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDCTr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDCTr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDCTr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDCTr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDCTr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDCTr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDCTr Industrial Control Measurement AC/DC Hall Current Sensor Transformer 1000: 1 120ADC 15VDC

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier