222-Lxn DC Leakage Current AC Sensor Transformers

Hubei Tianrui Electronic Co., Ltd.
  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Hall Type Technology: Utilizes semiconductor integrated Hall effect for precise current measurement.
  • Wide Detection Range: Measures DC, AC, transient peak, and arbitrary waveform currents accurately.
  • High Accuracy Grade: Precision grade ranging from 0.2 to 1 with linearity under 1% FS.
  • Customizable Options: Offers customized secondary rated output voltage and primary current measurement ranges.
  • Robust Insulation: Provides 2.5kV insulation voltage between primary and secondary circuits.
  • Low Power Consumption: Current consumption is less than 30 mA with no insertion loss.
  • Multiple Certifications: Certified with ISO, CE, and RoHS standards for global compliance.

Product Images of 222-Lxn DC Leakage Current AC Sensor Transformers

222-Lxn DC Leakage Current AC Sensor Transformers pictures & photos
222-Lxn DC Leakage Current AC Sensor Transformers
222-Lxn DC Leakage Current AC Sensor Transformers pictures & photos
222-Lxn DC Leakage Current AC Sensor Transformers
222-Lxn DC Leakage Current AC Sensor Transformers pictures & photos
222-Lxn DC Leakage Current AC Sensor Transformers
222-Lxn DC Leakage Current AC Sensor Transformers pictures & photos
222-Lxn DC Leakage Current AC Sensor Transformers
222-Lxn DC Leakage Current AC Sensor Transformers pictures & photos
222-Lxn DC Leakage Current AC Sensor Transformers
222-Lxn DC Leakage Current AC Sensor Transformers pictures & photos
222-Lxn DC Leakage Current AC Sensor Transformers
222-Lxn DC Leakage Current AC Sensor Transformers pictures & photos
222-Lxn DC Leakage Current AC Sensor Transformers
  • 222-Lxn DC Leakage Current AC Sensor Transformers pictures & photos
    222-Lxn DC Leakage Current AC Sensor Transformers
  • 222-Lxn DC Leakage Current AC Sensor Transformers
    222-Lxn DC Leakage Current AC Sensor Transformers
  • 222-Lxn DC Leakage Current AC Sensor Transformers
    222-Lxn DC Leakage Current AC Sensor Transformers
  • 222-Lxn DC Leakage Current AC Sensor Transformers
    222-Lxn DC Leakage Current AC Sensor Transformers
  • 222-Lxn DC Leakage Current AC Sensor Transformers
    222-Lxn DC Leakage Current AC Sensor Transformers
  • 222-Lxn DC Leakage Current AC Sensor Transformers
    222-Lxn DC Leakage Current AC Sensor Transformers
  • 222-Lxn DC Leakage Current AC Sensor Transformers
    222-Lxn DC Leakage Current AC Sensor Transformers

Find Similar Products

Product Description

Specification 10mA/5V 50mA/5V 200mA/5V Unit
IPN Primary Rated Input Current (DC) 10 50 200 mA
IP Primary Current Measurement Range 0~15 0~75 0~300 mA
VSN Secondary rated output voltage(DC) 5 V
VC The Power Supply Voltage ±12~15(±5%) V
IC Current Consumption <30 mA
Vd Insulation Voltage Between primary and secondary circuits:2.5kV/50Hz/1min  
εL Linearity <1 %FS
X Precision TA=25ºC:≤±0.5 %
V0 Offset Voltage TA=25ºC:≤±50 mV
VOT Offset Voltage Temperature Drift Ip =0 TA =-40~+80ºC:≤±1.5 mV/ºC
Tr Response Time ≤120 mS
TA Working Temperature -40~+80 ºC
TS Storage Temperature -45~+85 ºC
RL Load Resistance TA=25ºC:≥10 kΩ

FUNCTION :
MEASURE THE ARBIRARY WAVEFORM CURRENT ,SUCH AS DC AC ,TRANSIENT PEAK ,PAMMETERS MEASUREMENT .BETTER LINEARITY ,

GOOD DYNAMIC PERFPRMANCE WORKING HANDWIDE ,STRONG OVERLOAD ABILITY ,

Application :

Used in electric power, industrial automation, machinery, automotive, home appliances and other industries and fields

Brief introduction of principle :

The magnetic field generated by the primary current Ip flowing through the conductor is concentrated in the magnetic ring. The magnitude of this magnetic field is proportional to the current flowing through the conductor. The Hall element in the magnetic ring air gap measures and amplifies the output, and the output voltage Vs is reflecting the primary current Ipo accurately.

Characteristic :

Highly insulated between the primary and secondary side

Small size ,light weight

No insertion loss ,low power consumption

Wide detection range

 222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers

 

222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers222-Lxn DC Leakage Current AC Sensor Transformers

About the Supplier

Watch Video
Watch Video
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.
Hubei Tianrui Electronic Co., Ltd.

About Our Factory & Business Background

Address
No. 8, Chuangye Avenue, Tianmen Economic Development Zone, Tianmen City, Hubei Province, Tianmen, Hubei, China
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main Products
Current Transformer, Current Sensors, Rogowski Coil, Voltage Transformer, AC DC Transmitter, Open Close Current Transformer, Inductomers, Power Transformer, Hall Sensor, Zero Sequence Current Transformer

Our Industry Experience & Global Business Record

Export Year
2015-12-12
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

Can the sensor measure different types of currents?
Yes, it measures arbitrary waveform currents including DC, AC, and transient peaks.
What is the response time of the sensor?
The response time is less than or equal to 120 milliseconds.
Is the product customizable?
Yes, customization is available for secondary rated output voltage and primary current measurement range.
What is the insulation voltage rating?
The insulation voltage between primary and secondary circuits is 2.5kV at 50Hz for 1 minute.
What certifications does the sensor have?
The sensor holds ISO, CE, and RoHS certifications.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now