Customization: | Available |
---|---|
Application: | Electronic, Instrument, Position Sensor, Audio, Lighting |
Type: | Current Transformer |
Still deciding? Get samples of US$ 10/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
FK/FK Series open current transformers
FK/FK Series
The FK/FK Series of power transformers are equipped with an open core for easy installation on site. Through the principle of electromagnetic induction, the measured source is isolated from personnel and equipment, effectively protecting personnel and property safety. The FK/FK Series provides a variety of apertures and specifications to meet different use and installation requirements. At the same time, we have a professional design team to accept customized products to meet all your needs.
Application:
Can be applied to engineering project transformation, rural power network transformation, power distribution, building energy consumption, current detection, power monitoring, and energy consumption analysis.
For power harvesting,
Metering loop electrical parameter acquisition.
Electrical performance/p> parameters |
Operation temperature | -40ºC~+70ºC | Relative humidity | ≤90% |
Voltage level | 0.4/0.66/0.72KV | Linear range | 5%~120% | |
Rated input current | 0~1500A | Rated frequency | 50/60Hz | |
Rated capacity | 0~5VA | Power frequency withstand voltage | 3KV/min | |
Accuracy class | 0.5,1.0 | Dielectric strength | 1000MΩ/500V/min | |
Mechanical structure parameters |
Shell | PA/PC Flammability rating 94-V0 | Output method | PVC Sheathed cable/RJ12 Crystal terminal/PS/2Round head male interface |
Winding bobbin | PBT | Opening-closing structure | snap | |
Core material | Silicon steel/manganese zinc ferrite | Construction plan | Nylon cable ties bundled and fixed cables |
Shape and installation dimensions | |||||||
Product model | rated input | rated output | accuracy class | Dimensions(mm) | |||
D | L | W | H | ||||
TRFK-10A | 0~75A | 0~50mA (0~1.0V) | 0.2 0.3 0.5 0.5s |
9 | 34.5 | 37.5 | 45 |
TRFK-16A | 0~150A | 0~100mA (0~2.5V) | 15 | 40.5 | 42.5 | 52 | |
TRFK-24A | 0~250A | 0~100mA (0~5.0V) | 22.5 | 54 | 47 | 71 | |
TRSK-36-1A | 0~300A | 0~100mA (0~7.0V) | 35 | 61 | 53 | 81 | |
TRSK-36A | 0~500A | 0~100mA (0~7.0V) | 35 | 66 | 53 | 87 | |
TRSK-50-1A | 0~600A | 0~100mA (0~7.0V) | 49 | 81 | 59 | 107.5 | |
TRSK-50A | 0~800A | 0~100mA (0~7.0V) | 50 | 88 | 59 | 114 | |
TRSK-10A | 5~100A | 0~200mA (0.5VA) | 0.5 0.5s 1.0 3.0 |
9 | 34.5 | 37.5 | 45 |
TRFK-16A | 5~150A | 0~1A (0.5VA 1VA) | 15 | 40.5 | 42.5 | 52 | |
TRFK-24A | 10~300A | 0~5A (0.5VA 2.5VA) | 22.5 | 54 | 47 | 71 | |
TRSK-36-1A | 10~500A | 0~5A (0.5VA 2.5VA) | 35 | 61 | 53 | 81 | |
TRSK-36A | 10~600A | 0~5A (0.5VA 3.75VA) | 35 | 66 | 53 | 87 | |
TRSK-50-1A | 10~1000A | 0~5A (0.5VA 3.75VA) | 49 | 81 | 59 | 107.5 | |
TRSK-50A | 10~1500A | 0~5A (0.5VA 5VA) | 50 | 88 | 59 | 114 |